RFID: identify assets at defined read points
An RFID system uses a reader and a tag. In passive RFID, the reader supplies the energy used by the tag to respond, commonly through backscatter. The tag does not need its own battery for the radio response. This makes passive RFID attractive for identifying large populations of tagged items or assets when the workflow can bring them through a known read zone. In a terminal, possible use cases include container or chassis identification at a gate, equipment identification at a maintenance or inspection point, and confirmation that a tagged item passed a defined transfer location.
Active RFID tags contain a power source and transmit a signal that receiving infrastructure can detect. Depending on the system, fixed readers may use those transmissions to estimate a tag's location or presence. Active tags can support longer-range asset visibility than passive tags, but introduce battery management, tag cost, and receiver-infrastructure considerations. Passive and active RFID should therefore be evaluated as distinct designs, not treated as one interchangeable tracking method.
A successful read establishes that a tag was observed in a reader's effective zone. It does not automatically provide continuous coordinates, prove that the associated container was correctly loaded, or confirm the completion of a handover. Reader placement, antenna orientation, tag mounting, metal surfaces, adjacent containers, vehicle speed, and the physical geometry of the lane all affect read performance.